DATA CENTRE TEAM
KAE has in-depth experience on design and delivery of high efficiency data centres, communication buildings, trading floors and large computer rooms. KAE has undertaken in excess of 125 data centre projects.
Data Centre Team
Typical Data Centre Requirements
Services we provide
Sample Projects
Data Centre Team KAE has a specialist data centre team able to assist with any project. KAE has a proven track record in the delivery of similar projects and our proven ability to work seamlessly with our clients.
KAE has delivered many large data centre developments and are able to provide expert and dedicated staff for this project.
KAE will deliver the following key attributes:
- Technical expertise
- ESD focus with achievement of green star and ABGR results
- Provision of new technology including co/tri generation
- On time quality design
- Quality design providing low energy, long life and reliable systems
- Compliance with data centre standards and BCA & related standards
- Enthusiasm and team commitment
 |
 |
| Jorgen Knox CV |
Paul McAleese CV |
 |
 |
| Jacob Theodorou CV |
John Gardner CV |
 |
|
| Mal Clarke CV |
|
Typical Data Centre Requirements
Typically data centre projects require the provision of highly reliable power supplies and cooling systems.
System selections are made thorough analysis of the whole-of life options and the reliability options, with report.
Typically usage: secure 24/7 critical operational facility with limited, if any, ability to tolerate disruption.
Services we provide
KAE provide services for Mechanical, Electrical, Communications, Data, Hydraulic and ESD Services. KAE also actively participate in associated works including:
- Risk and Opportunity
- Build ability
- Budget control
KAE designs consider:
- The economics of the design
- The availability of proven technology
- The integration and compatibility with existing equipment, systems and infrastructure
- Equipment and installation compliance
- Whole of Life (WOL) performance
- Ecologically Sustainable Development (ESD) performance targets
KAE typically provide the following services:
- Liaison with client and team
- Existing Services Condition Report
- Preparation of return briefs
- Preparation of room data sheets
- Preparation of concept design and reports including:
- Central plant,
- Alternate power supply report
- Air conditioning options
- Co/tri Generation report
- Detailed design
- Risk Management meeting attendance & participation
- Site Phase attendance
Mechanical Services
- Air Conditioning to data centre floors, including computerised heat load calculations
- Air Conditioning or ventilation to UPS rooms
- Ventilation to emergency generator rooms
- AS1668.2 ventilation requirements
- AS1668.1 requirements as required.
- Ventilation to sub stations
- Central plant design for selected systems (Water Cooled or Air Cooled Chillers or Absorption Chillers or Combined heat and power etc).
- BMCS
Electrical Scope of Works
- Substation
- Alternative gas driven Fuel Cell
- Consumer Mains
- Main Switchboard
- Generators
- Rotary UPS
- Metering
- Power Factor Correction
- Distribution Boards
- Submains
- Lightning protection
- Surge Protection
- RFI Shielding
- Earthing
- Luminaires
- Energy Management Lighting Control
- External Lighting
- Exit and Emergency Lighting
- General Power & Lighting sub-circuits
- Power Outlets (switched socket outlets)
Communication
- Building Distributor
- Lead-in and Backbone Data Single Mode Optical Fibre (SMOF) cabling
- Lead-in and Backbone Category 3 Cabling
- Communication Cabinets
- Horizontal Category 6 cabling and RJ45 outlets
- Patch leads and flyleads.
- MATV Free to Air system
Hydraulic Design
- Sanitary plumbing and drainage
- Roof drainage and storm water management
- Storm Water Reports
- Domestic hot and cold water reticulation systems
- Natural gas reticulation
- Rainwater Harvesting
Combined Heat & Power
KAE undertake analysis of trigeneration, cogeneration and other alternative power sources to determine suitable and cost-effective systems for each project.
Sample Projects
MECHANICAL
Kent
Street Data Centre [click for datasheet]
18 storey dedicated CBD data centre. 800 m2 raised floor.
KAE provided all services including raised floor for this project. Services included new central plant chillers, close control air conditioning, fire suppression, communications, electrical, security, bmcs etc
Earth
Satellite Station
[click for datasheet]
10,000 m2 Earth Satellite station, delivering NSW's
wireless communications via orbiting satellites.
Wollongong Data Centre
KAE provided all services for this 4 storey Data
Centre refurbishment.
This project including all new chillers and cooling towers and associated infrastructure replacement whilst maintaining building operation.
Canberra Defence Data Centre [click for datasheet]
The KAE team delivered Architectural, Structural, Electrical, Fire, Hydraulic and Mechanical services for a new Tier 3 data centre in Canberra. "We were able to undertake this project, in rapid fashion, due to our in house expertise and extensive data centre project experience" Paul McAleese - KAE.
Project Highlights:
- 3 off 1MVA transformers
- Mission critical N + 1 power supply
- 100% UPS back up systems
- N + 1 central cooling plant, with free cooling chillers
- Raised floor design delivering 1200 watts/square meter cooling
- Inergen fire suppression system
- Fast track design
- 3 off 1MVA Standby generators and bulk fuel storage
Canberra Defence Data Centre - due diligence reports
KAE provided a detailed Services & Infrastructure due diligence report
for this strategic Defence Data Centre.
Issues:
Our clients require KAE to understand and resolve the following
critical issues important to Data Centres:
- No loss of power
- No loss of Air Conditioning
- Emergency Power Supplies
- Duplicate systems (Power and HVAC)
- Fire Systems
- Alarm Notification
- Equipment expansion
- Energy Efficiency
- Flexibility
- Stable Environment
- High Heat Loads
- Latest Technology
Dalley Street Data Centre
KAE undertook the detailed design of this large Sydney based data centre allowing for the building to be decanted. This allowed for a large multi- storey mixed development to occur on the site.
Management
KAE can manage your new data centre... we have to date, delivered many projects (individual and groups of sites) from initial client briefing through to handover. Services we
provide are summarised below:
- Client Brief Analysis
- Program formation
- Site Investigation
- Liaison with Utilities
- Detailed Design (including Architectural, Structural etc)
- DA Application
- Tender issue of documentation
- Tender evaluation and recommendation
- Award of contract on behalf of client
- Site phase duties including site meetings, MOP approval etc
- Testing and commissioning witnessing
- Project handover
ELECTRICAL
Kent Street Data Centre(KAE) - click for datasheet
18 storey dedicated CBD data centre. 800 m2 raised floor.
Earth Satellite
10,000 m2 Earth Satellite station, delivering NSW's wireless communications via orbiting satellites.
Wollongong Data Centre
KAE provided all services for this 4 storey Data Centre refurbishment.
Canberra Defence Data Centre
KAE provided a detailed Services & Infrastructure due diligence report for this strategic Defence Data Centre.
Issues
Our clients require KAE to understand and resolve the following critical issues important to Data Centres:
- No loss of power
- No loss of Air Conditioning
- Emergency Power Supplies
- Duplicate systems (Power and HVAC)
- Fire Systems
- Alarm Notification
- Equipment expansion
- Energy Efficiency
- Flexibility
- Stable Environment
- High Heat Loads
- Latest Technology
HYDRAULICS / FIRE
Kent Street Data Centre
This project is an 18 storey voice & data communications hub supporting
Big Pond internet and Fox TV. This exchange is one of Sydney’s most
critical exchanges.
The building services infrastructure is required to achieve a very high
level availability. Construction of this project was completed in June
2003, and comprised the full fit out of a 1,000 sq.m shell, including
augmentation of the building existing chilled water and power supply infrastructure
to support up to 600W/sq.m equipment loads.
KAE undertook the hydraulic services design, and construction administration,
for this new 1,000 sq.m data centre within Sydney’s premier telephone
exchange building.
This project highlights KAE’s expertise in successfully delivering
a fully coordinated, multi-disciplinary design solution to a technically
demanding client’s brief.
The hydraulic design provided for air conditioning condensate removal,
computer floor flood protection, sub floor waterproofing sprinkler pipe
work etc
ACOUSTICS Various Data Centres, including (KAE):
| Wollongong |
Burwood |
Kogarah |
Arndell Park |
| Gorokan |
Castle Hill |
Como |
Riverstone |
| Sawtell |
Lidcombe |
Campbelltown |
Gosford |
| Walgett |
Silverwater |
Newcastle |
Kincumber |
| Coonamble |
Brooklyn |
Boolaroo |
Lake Munmorah |
| Coonabarabran |
Cootamundra |
East Maitland |
Kariong |
| Alstonville |
Swansea |
Pendle Hill |
St Marys |
| Goonellabah |
Pennant Hills |
Tenterfield |
Botany |
| Albion Park |
Petersham |
Ashfield |
Waverley |
| Hurstville |
Richmond |
Seven Hills |
Five Dock |
| Randwick |
Bathurst |
Berkley Vale |
Warilla |
| Manly |
Coogee |
Narrabeen |
Adamstown |
| Matraville |
Bankstown |
Lakemba |
Sutherland |
| Helensburg |
Mt Kuring Gai |
Nelson Bay |
|
FACILITIES MANAGEMENT
Coming soon...
STRUCTURAL
East Maitland
Data Centre
KAE documented a standalone building to house the central plant chillers
and associated sub-systems for this building.
The new building comprised a single storey brick and precast concrete
walled building (approximately 150 sq.m) complete with concrete floor
slab and steelwork framed roof. The roof structure allowed for the support
of significant acoustic treatment for the 3 off air cooled chillers.
Compliance with Council requirements and DA formed a major part of the
design.
Wollongong Data Centre
KAE documented a new 200 square metre roof platform to house the air conditioning
plant for this project. The platform was designed to support 6 cooling
towers and one air cooled radiator along with associated acoustic treatment
for the towers and screening.
Other projects
undertaken to date by our staff include:
- Sawtell Data Centre (KAE);
- Gorokan, Blakehurst, and Nelson Bay Data Centres (KAE);
BUILDING SURVEY REPORTS
Coming soon...
|